{"product_id":"aritech-ts1061-tecom-dual-wiegand-interface-unit","title":"Aritech TS1061 Tecom ChallengerPlus Dual Wiegand Interface Unit (NEW In Box)","description":"\u003cp\u003eThe Aritech TS1061 is a dual Wiegand interface unit for the Tecom ChallengerPlus and the Tecom Network Access Controller, sold in Australia under the Tecom part number S7017A. It connects Wiegand technology card readers to the system and expands door capacity, providing two reader ports, two relay outputs, four inputs and a tamper input on a single board.\u003c\/p\u003e\n\u003cp\u003eIt is an RS-485 data bus device with plug on connectors for the bus and for lock power, and can run up to 1,500 metres from the control panel. Power is 11 to 14 V DC taken from the data bus or from an external 12 V supply, with the board drawing around 80 mA and the connected readers sharing a 450 mA budget. The firmware is remotely upgradeable through CTPlus installer software, and multiple end of line resistor values are supported. This is the newest generation module of its type in the Tecom range and carries a seven year warranty class on the distributor label.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Aritech (Carrier)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e Tecom Dual Wiegand Interface Unit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e TS1061\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlternate Part Number:\u003c\/strong\u003e TECOM S7017A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Wiegand reader interface and door expansion module, PCB only\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReader Ports:\u003c\/strong\u003e 2 x Wiegand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e 4 plus 1 tamper input\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBus:\u003c\/strong\u003e RS-485 data bus with plug on connectors for the bus and NAC lock power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 11 to 14 V DC from the RS-485 data bus or an external 12 V supply\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 80 mA, or 73 mA from a 12 V supply standalone\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReader Budget:\u003c\/strong\u003e Connected Wiegand readers draw a combined maximum of 450 mA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Cable Distance:\u003c\/strong\u003e 1,500 m from the control panel\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAddressing:\u003c\/strong\u003e ChallengerPlus COMMS 1 and 2, addresses 1 to 12, twelve units per bus. Network Access Controller BUS 1 addresses 1 to 15, BUS 2 addresses 1 to 16\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Panels:\u003c\/strong\u003e Tecom ChallengerPlus (TS-CHPLUS) and Tecom Network Access Controller (TS1066, TS1067)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware:\u003c\/strong\u003e Remote flash upgradeable via CTPlus installer software\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnd Of Line Resistors:\u003c\/strong\u003e Multiple values supported\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 128 x 78 x 21 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 225 to 255 g depending on the manufacturer document\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 50 degrees C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure:\u003c\/strong\u003e PCB only. Must be installed in an ENC-LGE Large Enclosure, not supplied\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Accessory:\u003c\/strong\u003e TS1066P adaptor plate for retrofit installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e RCM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Class On Label:\u003c\/strong\u003e 7 year\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Number:\u003c\/strong\u003e 268240090506\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Manufacture:\u003c\/strong\u003e China\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e New in box\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTwo Wiegand reader ports on one board\u003c\/li\u003e\n\u003cli\u003eTwo relay outputs, four inputs and a tamper input\u003c\/li\u003e\n\u003cli\u003eRS-485 bus device, up to 1,500 m from the panel\u003c\/li\u003e\n\u003cli\u003eUp to twelve units on a ChallengerPlus COMMS bus\u003c\/li\u003e\n\u003cli\u003eFirmware upgradeable remotely through CTPlus\u003c\/li\u003e\n\u003cli\u003eSeven year warranty class on the Australian distributor label\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdding doors to a Tecom ChallengerPlus access control system\u003c\/li\u003e\n\u003cli\u003eConnecting existing Wiegand card readers to a Tecom system\u003c\/li\u003e\n\u003cli\u003eExpanding a Tecom Network Access Controller installation\u003c\/li\u003e\n\u003cli\u003eRetrofitting Wiegand readers with the optional TS1066P adaptor plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne TS1061 board\u003c\/li\u003e\n\u003cli\u003eInstallation manual\u003c\/li\u003e\n\u003cli\u003eMounting screws and standoffs\u003c\/li\u003e\n\u003cli\u003eTerminal connectors and end of line resistors\u003c\/li\u003e\n\u003cli\u003eRS-485 and lock power cables and an earth lead\u003c\/li\u003e\n\u003cli\u003eNo enclosure, no readers and no power supply are included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cp\u003ePlease read this before ordering. This module works with the Tecom ChallengerPlus and the Tecom Network Access Controller only. It will not work with Challenger10 or Challenger V8. This is the most common cause of a return on this part, so please confirm your panel before buying.\u003c\/p\u003e\n\u003cp\u003eIt is not an Aritech ATS or Advisor Advanced part.\u003c\/p\u003e\n\u003cp\u003eThis is a bare PCB and the installation manual specifically requires it to be mounted in an ENC-LGE Large Enclosure, which is not supplied. No Wiegand readers, lock hardware or power supply are included.\u003c\/p\u003e\n\u003cp\u003eBus address limits apply. A maximum of twelve units can sit on a ChallengerPlus COMMS bus, and fifteen or sixteen on a Network Access Controller bus depending on which bus is used.\u003c\/p\u003e\n\u003cp\u003eWiegand readers connected to this unit share a 450 mA supply budget.\u003c\/p\u003e\n\u003cp\u003eInstallation should be carried out by a licensed security technician.\u003c\/p\u003e\n\u003cp\u003eThe item is new and supplied in the manufacturer's box. The packaging may show minor shelf wear from storage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping from Sydney, Australia.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Aritech","offers":[{"title":"Default Title","offer_id":52952475173181,"sku":"S4281","price":176.26,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/8931\/9485\/files\/20260831_170826.jpg?v=1788194370","url":"https:\/\/indrelec.com.au\/products\/aritech-ts1061-tecom-dual-wiegand-interface-unit","provider":"Indrelec","version":"1.0","type":"link"}